or call +91 91766 77448

Combined Vibration Climatic Test Chamber

With Vibration Shaker Vertical and Horizontal
Combined_main

Combined Vibration Climatic Test Chamber

HIACC’s AGREE Test Chambers offer adaptability to meet evolving environmental testing requirements. These chambers are available in temperature-only or temperature and humidity configurations, providing rapid thermal change rates ranging from 5°C up to 20°C. Notably, these chambers can seamlessly transform into vibration chambers when integrated with an Electrodynamic vibration shaker or repetitive shock vibration table.

This versatility extends the chamber’s utility, allowing it to function independently as a temperature environmental chamber or for combined environmental testing. Originally designed for the defense and aerospace industry to comply with IEC 60068 and MIL-STD for temperature, humidity, and vibration tests, AGREE Vibration Chambers have since been adapted for reliability testing, qualification, and Environmental Stress Screening (ESS) across various industries, including electronics, aerospace, automotive, and telecommunications.

  • Temperature Range: -70˚C to +180˚C (Cascade) and -40˚C to +180˚C (Single)
  • Humidity Range: 10% RH to 98% RH
  • Slide-Out, Adjustable Product Shelf
  • A Lockable, One-Handed Door Latch
  • Two 4″ (100mm) Circular Port Plugs
  • TCP/IP and Serial Communication
  • Frost-Free Operation
  • Non-settling oven-grade rigid stone wool insulation, 0.25 K factor
  • Heavy-Duty Casters Swivel provides portability and is equipped with leveling pads for added stability.
  • Energy Saving and Low-GWP Refrigerant R404A and R23
  • Silicone two-piece door gasket, featuring mitered and vulcanized corners for a secure and durable seal.
  • A multi-pane fog-free, tempered heated viewing window minimizes condensation with interior light.
  • The interior liner is constructed with continuous TIG welding using 304 stainless steel, ensuring durability and quality.
  • Maintenance is made simple with full three-sided access to the base-mounted system components, facilitating ease of service and upkeep

With Kilma, you can save both time and money

Klima is customisable to conduct testing as per your choice. Below are some of the frequently used test standards in Klima.

IEC 60068 - 2 - 30, 2005, Environmental testing Part 2-30:, Tests: Damp heat, cyclic,
IEC 60068 - 2 - 78, 2012, Environmental testing Part 2-78:, Tests: Damp heat, steady state
IEC 60068 - 2 - 1, 2007, Environmental testing Part 2-1:, Tests: Cold

Technical Specifications

 Specification/ Model KLIMA – 120/-40C/3K KLIMA -120/-70C/3K KLIMA – 225/-40C/3K KLIMA -225/-70C/3K KLIMA – 340/-40C/3K KLIMA -340/-70C/3K KLIMA – 450/-40C/3K KLIMA -450/-70C/3K KLIMA -580/-40C/3K KLIMA -580/-70C/3K KLIMA – 1000/-40C/3K KLIMA -1000/-70C/3K KLIMA – 1500/-40C/3K KLIMA -1500/-70C/3K
TEST SPACE DIMENSIONS
Test space volume Ltr. 120L 225L 340L 448L 576L 1000L 1500L
Width mm 500 600 700 700 800 1000 1000
Depth mm 400 500 600 800 800 1000 1500
Height mm 600 750 800 800 900 1000 1000
PERFORMANCE DATA FOR TEMPERATURE TESTS
Maximum temperature °C 180
Minimum temperature discontinuous °C -40 -70 -40 -70 -40 -70 -40 -70 -40 -70 -40 -70 -40 -70
Rate of temperature change, cooling  °C/min 3
Rate of temperature change, heating °C/min 3.5
Temperature deviation, in time °C ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1
Heat compensation, max. at +20 °C W 850 1000 850 1000 900 1100 900 1100 1000 1200 1000 1200 1000 1200
PERFORMANCE DATA FOR CLIMATE TESTS
Maximum temperature °C 85
Minimum temperature  °C 10
Humidity range  %RH 10…98
Humidity deviation, in time %RH ±1…±3
Temperature deviation, in time %RH ±0,1 … ±0,3
Test Standard Compliance IEC-60068, IEC-60749, IEC-61747, MIL-STD, ISO16750, ASTM, SAE, BIS & 50 other standards
TEST SPACE LOADING CAPACITY
Load, max. kg 80 100 100 100 100 100 100
Load per grid kg 20 20 25 25 30 30 30
Possible number of insert grids piece 4 5 6 6 7 7 7
POWER/CONNECTION DATA
Voltage rating V 3/N/PE AC 415V±10% 50Hz other voltages and frequencies optional
Connected Load kW 8.5 11 9.5 12 10 13 11.5 14 14.5 17 16 19.5 17 20
Sound pressure level dB(A) 72 74 72 74 72 74 73 74 73 74 73 74 73 74
Total weight kg 450 500 490 540 540 600 600 680 720 780 820 900 900 1000
Refrigerant type R404A R404A R404A R404A R404A R404A R404A R404A R404A R404A R404A R404A R404A R404A
R23 R23 R23 R23 R23 R23 R23
(*) The performance data refer to an operating room (ambient) temperature of +26 °C , 415 V/50 Hz nominal voltage, without test specimen and without accessories

Options

(Special accessories on customer request)

Additional Port Holes 50MM, 100MM, 125MM& 150MM
Floor Loading Capacity (Customizable)
Air Dryer for Low RH Applications
Heavy duty Customized Shelves
Water-Cooled Refrigeration Systems
Remote Refrigeration/ Condensing Unit
Booster Cooling through LN2 up to -150 Deg C

Touchscreen Controller

HIACC’s flagship touchscreen controller provides ease for doing complex testing. It is equipped with USB access and Ethernet, with a range of flexibility. Following are some of the features of the controller.

Chamber Home
Chamber Home
Chamber Menu-Index New
Chamber Menu
Process MIMIC
Process MIMIC
Chamber Diagnostics
Chamber Diagnostics
Alarm Summary - New
Alarm status

Let's Talk About Your Needs

Select Industry*
Select type of Products*
Select Products*
Select Products*