or call +91 91766 77448

Combined Vibration Climatic Test Chamber

For Combined Vibration and Climatic Simulation

Combined Vibration Climatic Test Chamber

KLIMA range of AGREE Test Chambers, designed to meet diverse environmental testing needs with unparalleled adaptability. Available in temperature-only or temperature and humidity configurations, these chambers offer rapid thermal change rates ranging from 5°C to 20°C.

What sets the KLIMA AGREE Test Chambers apart is their seamless transformation into vibration chambers when integrated with an Electrodynamic vibration shaker or repetitive shock vibration table. This versatility extends the chamber’s utility, allowing it to function independently as a temperature environmental chamber or for combined environmental testing.

With Kilma AGREE, you can save both time and money.

Klima AGREE is customizable to conduct testing as per your choice. Below are some of the frequently used test standards in Klima.

IEC 60068 - 2 - 30, 2005, Environmental testing Part 2-30:, Tests: Damp heat, cyclic,
IEC 60068 - 2 - 78, 2012, Environmental testing Part 2-78:, Tests: Damp heat, steady state
IEC 60068 - 2 - 1, 2007, Environmental testing Part 2-1:, Tests: Cold

Technical Specifications

 Specification/ Model KLIMA- 120/-40C/3K KLIMA-120/-70C/3K KLIMA- 225/-40C/3K KLIMA-225/-70C/3K KLIMA- 340/-40C/3K KLIMA-340/-70C/3K KLIMA- 450/-40C/3K KLIMA-450/-70C/3K KLIMA-580/-40C/3K KLIMA-580/-70C/3K KLIMA- 1000/-40C/3K KLIMA-1000/-70C/3K KLIMA- 1500/-40C/3K KLIMA-1500/-70C/3K
TEST SPACE DIMENSIONS
Test space volume Ltr. 120L 225L 340L 448L 576L 1000L 1500L
Width mm 500 600 700 700 800 1000 1000
Depth mm 400 500 600 800 800 1000 1500
Height mm 600 750 800 800 900 1000 1000
PERFORMANCE DATA FOR TEMPERATURE TESTS
Maximum temperature °C 180
Minimum temperature discontinuous °C -40 -70 -40 -70 -40 -70 -40 -70 -40 -70 -40 -70 -40 -70
Rate of temperature change, cooling  °C/min 3
Rate of temperature change, heating °C/min 3.5
Temperature control accuracy, in time °C ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1
Heat compensation, max. at +20 °C W 850 1000 850 1000 900 1100 900 1100 1000 1200 1000 1200 1000 1200
PERFORMANCE DATA FOR CLIMATE TESTS
Maximum temperature °C 85
Minimum temperature  °C 10
Humidity range  %RH 10…98
Humidity deviation, in time %RH ±1…±3
Temperature deviation, in time %RH ±0,1 … ±0,3
Test Standard Compliance IEC-60068, IEC-60749, IEC-61747, MIL-STD, ISO16750, ASTM, SAE, BIS & 50 other standards
TEST SPACE LOADING CAPACITY
Load, max. kg 80 100 100 100 100 100 100
Load per grid kg 20 20 25 25 30 30 30
Possible number of insert grids piece 4 5 6 6 7 7 7
POWER/CONNECTION DATA
Voltage rating V 3/N/PE AC 415V±10% 50Hz other voltages and frequencies optional
Connected Load kW 8.5 11 9.5 12 10 13 11.5 14 14.5 17 16 19.5 17 20
Sound pressure level dB(A) 72 74 72 74 72 74 73 74 73 74 73 74 73 74
Total weight kg 450 500 490 540 540 600 600 680 720 780 820 900 900 1000
Refrigerant System type R404A R404A R404A R404A R404A R404A R404A R404A R404A R404A R404A R404A R404A R404A
R23 R23 R23 R23 R23 R23 R23

(*) Upon customer request, customized sizes are also available.

(*) Append request: Low GWP refrigerants of R449a, R448a, and R508B are available.

(*) The performance data refer to an operating room (ambient) temperature of +26°C, 415 V/50 Hz nominal voltage, without test specimen and without accessories.

(*) Sound Pressure Level: Using a calibrated instrument, the weighted sound pressure level was measured in free-field environments at a height of 1 meter from the floor and a distance of
1 meter from the equipment surface.

Options

(Special accessories on customer request)

Additional Port Holes: Choose from 50mm, 100mm, 125mm, and 150mm port holes to accommodate various connections.
Customizable Floor Loading Capacity: Tailor the chamber's floor loading capacity to meet your specific requirements.
Air Dryer for Low RH Applications: Ensure precise humidity control with an air dryer designed for low RH applications.
Heavy-duty Customized Shelves: Opt for heavy-duty shelves customized to support your specific testing needs.
Water-Cooled Refrigeration Systems: Enhance cooling efficiency with water-cooled refrigeration systems.
Remote Refrigeration/Condensing Unit: Access flexibility and convenience with a remote refrigeration/condensing unit.
Booster Cooling through LN2: Achieve ultra-low temperatures down to -150°C with booster cooling through LN2.

Touchscreen Controller

Experience seamless control with HIACC’s flagship Touchscreen Controller, designed to simplify even the most complex testing procedures. Featuring USB access and Ethernet connectivity, this controller offers unparalleled flexibility.

Here are some of its key features:

Chamber Home
Chamber Home
HIACC climatic chamber controller interface with temperature, humidity, and altitude settings.
Chamber Menu
Process MIMIC
Process MIMIC
Chamber Diagnostics
Chamber Diagnostics
Hiacc climatic chamber controller alarm summary chart, displaying alarm types and their activation states.
Alarm status

Let's Talk About Your Needs

Select Industry*
Select type of Products*
Select Products*
Select Products*

Download Request

Name*
Contact Number*
Email Id*