Stress Screening Test Chamber

For Stress Screening Simulations

Stress Screening Test Chamber

KLIMA range of Reach-in Environmental Stress Screening (ESS) chambers. Designed to offer flexibility in both size and performance, these chambers are tailored to meet your specific test applications. With temperature cycling rates ranging from 5°C to 20°C per minute, the KLIMA chambers provide versatility to accommodate a wide range of testing requirements.

  • Temperature Range: -70ËšC to +180ËšC (Cascade) & -40ËšC to +180ËšC (Single)
  • Humidity Range: 10% RH to 98% RH
  • Slide-Out, Adjustable Product Shelf
  • Lockable, One-Handed Door Latch
  • Two 4″ (100mm) Circular Port Plugs
  • Frost-Free Operation
  • TCP/IP and Serial Communication
  • Non-Settling Rigid Stone Wool Insulation
  • Heavy-Duty Swivel Casters with Leveling Pads
  • Energy Saving Refrigerants R404A and R23
  • Fog-Free Tempered Heated Viewing Window with Interior Light.
  • Continuous TIG Welding 304 Stainless Steel Interior Liner
  • Easy Maintenance with Three-Sided Access to Components

Simulate the Stresses, Uncover Weaknesses Environmental Stress Screening made Easy

KLIMA ESS is customizable to conduct testing as per your choice. Below are some of the frequently used test standards for ESS Testing

IEC 60068 - 2 - 30, 2005
IEC 60068 - 2 - 78, 2012
IEC 60068 - 2 - 1, 2007

Technical Specifications

Temperature change rate: 5°C/Min

Specification/ Model KLIMA – 120/-40C/5K KLIMA -120/-70C/5K KLIMA – 340/-40C/5K KLIMA -340/-70C/5K KLIMA – 450/-40C/5K KLIMA -450/-70C/5K KLIMA – 1500/-40C/5K KLIMA -1500/-70C/5K
TEST SPACE DIMENSIONS
Test space volume Ltr. 120L 340L 448L 1500L
Width mm 500 700 700 1000
Depth mm 400 600 800 1500
Height mm 600 800 800 1000
PERFORMANCE DATA FOR TEMPERATURE TESTS
Maximum temperature °C 180
Minimum temperature discontinuous °C -40 -70 -40 -70 -40 -70 -40 -70
Rate of temperature change, cooling (*) °C/min 5
Rate of temperature change, heating (*) °C/min 5
Temperature control accuracy, in time °C ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1
Heat compensation, max. at +20 °C W 850 1000 900 1100 900 1100 1000 1200
PERFORMANCE DATA FOR CLIMATE TESTS
Maximum temperature °C 85
Minimum temperature  °C 10
Humidity range  %RH 10…98
Humidity deviation, in time %RH ±1…±3
Temperature deviation, in time %RH ±0,1 … ±0,3
Test Standard Compliance IEC-60068, IEC-60749, IEC-61747, MIL-STD, ISO16750, ASTM, SAE, BIS & 50 other standards.
TEST SPACE LOADING CAPACITY
Load, max. kg 80 100 100 100
Load per Shelf (Tray) kg 20 25 25 30
Possible number of insert grids piece 4 6 6 7
POWER/CONNECTION DATA
Voltage rating V 3/N/PE AC 415V±10% 50Hz other voltages and frequencies optional
Sound pressure level dB(A) 72 74 72 74 73 74 73 74
Total weight kg 450 500 540 600 600 680 900 1000
Refrigerant System type R404A R404A R404A R404A R404A R404A R404A R404A
R23 R23 R23 R23

(*) Upon customer request, customized sizes are also available.

(*) Append request: Low GWP refrigerants of R449a, R448a, and R508B are available.

(*) The performance data refer to an operating room (ambient) temperature of +26°C, 415 V/50 Hz nominal voltage, without test specimen and without accessories.

(*) Sound Pressure Level: Using a calibrated instrument, the weighted sound pressure level was measured in free-field environments at a height of 1 meter from the floor and a distance of
1 meter from the equipment surface.

Temperature change rate: 10°C/Min, 15°C/Min, 25°C/Min

Specification/ Model KLIMA – 225/-40C KLIMA -225/-70C KLIMA -600/-40C KLIMA -600/-70C KLIMA – 1000/-40C KLIMA -1000/-70C
TEST SPACE DIMENSIONS
Test space volume Ltr. 225L 612L 1000L
Width mm 600 800 1000
Depth mm 500 850 1000
Height mm 750 900 1000
PERFORMANCE DATA FOR TEMPERATURE TESTS
Maximum temperature °C 180
Minimum temperature discontinuous °C -40 -70 -40 -70 -40 -70
Rate of temperature change, cooling (*) °C/min 10,15,25
Rate of temperature change, heating (*) °C/min 10,15,25
Temperature deviation, in time °C ±0,5 … ±1 ±0,5 … ±1 ±0,5 … ±1
Heat compensation, max. at +20 °C W 850 1000 1000 1200 1000 1200
PERFORMANCE DATA FOR CLIMATE TESTS
Maximum temperature °C 85
Minimum temperature  °C 10
Humidity range  %RH 10…98
Humidity deviation, in time %RH ±1…±3
Temperature deviation, in time %RH ±0,1 … ±0,3
Test Standard Compliance IEC-60068, IEC-60749, IEC-61747, MIL-STD, ISO16750, ASTM, SAE, BIS & 50 other standards
TEST SPACE LOADING CAPACITY
Load, max. kg 100 100 100
Load per Shelf (Tray) kg 20 30 30
Possible number of insert grids piece 5 7 7
POWER/CONNECTION DATA
Voltage rating V 3/N/PE AC 415V±10% 50Hz other voltages and frequencies optional
Sound pressure level dB(A) 72 74 73 74 73 74
Total weight kg 490 540 720 780 820 900
Refrigerant System type R404A R404A R404A R404A R404A R404A
R23 R23 R23

(*) Upon customer request, customized sizes are also available.

(*) Append request: Low GWP refrigerants of R449a, R448a, and R508B are available.

(*) The performance data refer to an operating room (ambient) temperature of +26°C, 415 V/50 Hz nominal voltage, without test specimen and without accessories.

(*) Sound Pressure Level: Using a calibrated instrument, the weighted sound pressure level was measured in free-field environments at a height of 1 meter from the floor and a distance of
1 meter from the equipment surface.

 

Options

(Special accessories on customer request)

Additional Port Holes: Choose from 50mm, 100mm, 125mm, and 150mm port holes to accommodate various connections.
Customizable Floor Loading Capacity: Tailor the chamber's floor loading capacity to meet your specific requirements.
Air Dryer for Low RH Applications: Ensure precise humidity control with an air dryer designed for low RH applications.
Heavy-duty Customized Shelves: Opt for heavy-duty shelves customized to support your specific testing needs.
Water-Cooled Refrigeration Systems: Enhance cooling efficiency with water-cooled refrigeration systems.
Remote Refrigeration/Condensing Unit: Access flexibility and convenience with a remote refrigeration/condensing unit.
Booster Cooling through LN2: Achieve ultra-low temperatures down to -150°C with booster cooling through LN2.

Touchscreen Controller

Experience seamless control with HIACC’s flagship Touchscreen Controller, designed to simplify even the most complex testing procedures. Featuring USB access and Ethernet connectivity, this controller offers unparalleled flexibility.

Here are some of its key features:

HomeScreenProgram_updated
Chamber Home
ChamberMenu_updated
Chamber Menu
MIMIC_update
Process MIMIC
Diagnostics_update
Chamber Diagnostics
Alarm_update
Alarm Status

Let's Talk About Your Needs

Select Industry*
Select type of Products*
Select Products*
Select Products*

Download Request

Name*
Contact Number*
Email Id*