Almost for all the vibration test applications, a Head Expander is required because the test specimen or the fixture is larger than the armature surface. In these cases, a Head Expander is used to provide a broader base for mounting the test specimen and fixtures.
A head expander is made of lightweight magnesium or less expensive aluminium. Many types of standardised Head Expanders are available or special customisation is also available to meet your requirements.
Head Expanders are designed with load support which enables larger test specimens to be mounted and tested safely on the shaker and reduces the risk of damage to the shaker suspension system. Head Expander design and customisation are available for your existing vibration test system as well. All of our Head Expanders have a strict requirement related to frequency, table weight, acceleration, amplitude uniformity and lateral movement and are designed to meet your standards.
Square Head Expander Specification | ||||||||
Model/Table diameter | -150 | -200 | -230 | -320 | -370 | -448 | -550 | -590 |
-240 | 480 | |||||||
HE3005 | 7 | 8 | 10 | − | − | − | Effective mass (kg) | |
2000 | 2000 | 2000 | Upper Limit Frequency (Hz) | |||||
HE4005 | 12 | 13 | 21 | − | − | − | − | − |
2000 | 2000 | 2000 | ||||||
HE5005 | 20 | 23 | 32 | 32 | 33 | − | − | − |
2000 | 2000 | 2000 | 2000 | 2000 | ||||
HE6005 | 29 | 37 | 38 | 40 | 40 | 53 | − | − |
1200 | 1300 | 1300 | 2000 | 2000 | 2000 | |||
HE7005 | − | − | 43 | 60 | 80 | 80 | − | − |
1000 | 2000 | 2000 | 2000 | |||||
HE8005 | − | − | 60 | 70 | 80 | 85 | 125 | 135 |
1000 | 1200 | 1300 | 1300 | 1800 | 1800 | |||
HE9005 | − | − | 80 | 95 | 95 | 100 | 120 | 120 |
700 | 800 | 1000 | 1000 | 1000 | 1000 | |||
HE10005 | − | − | 73 | 100 | 110 | 185 | 200 | 210 |
400 | 600 | 800 | 1000 | 1000 | 1200 | |||
HE11005 | − | − | − | − | − | 230 | 245 | 160 |
500 | 700 | 700 | ||||||
HE12005 | Effective mass (kg) | − | − | − | 250 | 265 | 280 | |
Upper Limit Frequency (Hz) | 400 | 500 | 500 | |||||
HE15005 | − | − | − | − | 350 | 400 | 420 | |
400 | 400 | 400 | ||||||
HE20005 | − | − | − | − | − | 900 | 1000 | |
300 | 300 |
Round Head Expander Specification | ||||||||
Model/Table diameter | -150 | -200 | -230 | -320 | -370 | -448 | -550 | -590 |
-240 | 480 | |||||||
HE300R | 7 | 8 | − | − | − | − | Effective mass (kg) | |
2000 | 2000 | Upper Limit Frequency (Hz) | ||||||
HE400R | 10 | 12 | 14 | 16 | − | − | − | − |
2000 | 2000 | 2000 | 2000 | |||||
HE500R | 20 | 21 | 23 | 30 | 32 | − | − | − |
2000 | 2000 | 2000 | 2000 | 2000 | ||||
HE600R | − | 20 | 30 | 33 | 38 | 38 | − | − |
1000 | 1800 | 1800 | 1800 | 2000 | ||||
HE700R | − | − | 33 | 58 | 69 | 70 | − | − |
800 | 1500 | 2000 | 2000 | |||||
HE800R | − | − | − | 60 | 70 | 72 | − | − |
800 | 1200 | 1500 | ||||||
HE900R | − | − | − | − | 85 | 100 | − | − |
1200 | 1200 | |||||||
HE1000R | − | − | − | − | − | 140 | 150 | 160 |
1000 | 1100 | 1100 | ||||||
HE1100R | − | − | − | − | − | 200 | 210 | 230 |
800 | 900 | 1000 | ||||||
HE1200R | − | − | − | − | − | 250 | 260 | 270 |
500 | 600 | 600 | ||||||
HE1500R | − | − | − | − | 330 | 350 | 400 | |
400 | 400 | 400 |